Menu
- Manual 2D Vision Measuring Systems Quick Image. User's Manuals Download user's manuals. Mitutoyo Brand Communication Materials Resources for Mitutoyo staff. I hereby declare my consent that my data is used for dispatching information and advertisement on industrial measuring technology via e-mail by Mitutoyo Europe GmbH.At all time I.
- The Mitutoyo 64PKA088A 172-868A Includes the PH-3515F Horizontal Bench-top Profile Projector with the QM Data Counter and Arm Mount. The QM Data adds new features of 2D coordinate measurement, image processing and more. The PH-3515F Profile Projector features a 14' diameter protractor screen with cross-hairs and staggered lines for easy alignment.
- Dec 16, 2013 QM Data 200 Demonstration Scott Pilcher. Unsubscribe from Scott Pilcher? Job Shop Measuring & Metrology Tips with Mitutoyo!.
- View and Download Mitutoyo Measuring Projector user manual online. Measuring Projector. Measuring Projector Projector pdf manual download. Also for: Pj-a3000, Pj-a3005f-150, Pj-a3010f-200, Pj-a3010f-100, Pj-a3005d-50, Pj-a3005r-50.
- 2D Data Processing Unit Users Manual (Operation Guide) Read this Users Manual thoroughly before operating the instrument. After reading, retain it close at hand for future reference. 99MBA038A SERIES No. 99MBA038A i CONVENTIONS USED IN THIS MANUAL Types of Notes The following types of notes are used in this manual to help the.
2D Data Processing Unit. User’s Manual (Operation Guide) Read this User’s Manual thoroughly before operating the instrument. After reading, retain it.
- Mitutoyo 264-156A QM-Data200 Processing Unit
$2,500.00 (You save $220.00)
MIT-264-156A
Usually ships in 5 days
Product Description
Mitutoyo Series 264 QM-Data200 Processing Unit
With SPC data output capability
You are reviewing the Mitutoyo QM-Data200 Data Processing Unit from Advanced Systems and Designs. The QM-Data200 is a geometric readout unit for optical profile projectors. Features 2-D coordinate measurement capabilities with simple key operation. Improves operator productivity and minimizes errors when used with the ASDQMS SmartCable Keyboard or Digimatic output FlashCable.
Details:
- Large LCD color screen
- Arm-Mount Type. Stand-Mount Model also available
- One key operation for frequently used measurements
- Tolerance zone measurement of data processing
- Measurement procedure and results can be saved to a USB drive
- SPC Data output; See SPC Data Collection Options below
- Click here for more technical information on this Mitutoyo gage
SPC Data Collection Options:
- To connect this Mitutoyo QM-Data200 Series 264-2-D Processing Unitto a computer and send data to Excel or Explorer based SPC programs, click this link to see our 600-22-QM200-KB-USB SmartCable with Keyboard output.
- Click the following link to see our 600-22-QM200-MTI Digimatic output FlashCable to send data to our GageMux or other devices that recognize the Digimatic format.
Advanced Systems and Designs - ASDQMS can provide all ranges and types of Mitutoyo Precision Gages from stock. Contact us for more information.
Please share your ZIP Code to find a nearby Best Buy to try out your next phone.A Samsung representative at Best Buy can set up a personal demonstration for your next galaxy device. A Samsung representative at Best Buy will call to schedule your Galaxy S10 try out. My h.p tablet user manual. Please share your ZIP Code to find a nearby Best Buy location, our Samsung representative, wants to know about you so they can assist you better., our Samsung representative at Best Buy, want to know about you to set up a personal demonstration on your next galaxy device. CUSTOMER RATINGS AND REVIEWS TERMS OF USEThese Terms of Use govern your conduct associated with the Customer Ratings and Review service offered by SAMSUNG (the 'CRR Service').
Product Reviews
This product hasn't received any reviews yet. Be the first to review this product!
Customers Who Viewed This Product Also Viewed
Related Products
- Digimatic FlashCable® for Mitutoyo LH-600E/EG Height Gage Display$169.00
- Digimatic FlashCable® for Mitutoyo QM-Data 200 Display$169.00
- SmartCable™ Keyboard for Mitutoyo QM-Data 200$229.00
- SmartCable™ Keyboard for Mitutoyo LH-600E/EG Display$229.00
- GageMux® USB Multiple Input Universal Gage Interface
Summary of the content on the page No. 1
No. 99MBA038A
SERIES No. 264
QM-Data 200
2D Data Processing Unit
User’s Manual
(Operation Guide)
Read this User’s Manual thoroughly
before operating the instrument. After reading,
retain it close at hand for future reference.
SERIES No. 264
QM-Data 200
2D Data Processing Unit
User’s Manual
(Operation Guide)
Read this User’s Manual thoroughly
before operating the instrument. After reading,
retain it close at hand for future reference.
Summary of the content on the page No. 2
Summary of the content on the page No. 3
CONVENTIONS USED IN THIS MANUAL Types of Notes The following types of notes are used in this manual to help the operator obtain reliable measurement data through correct instrument operation. IMPORTANT • An important note provides information essential to the completion of a task. You cannot disregard this note to complete the task. • An important note is a type of precaution, which if neglected could result in a loss of data, decreased accuracy or instrument malfunction/failure.
Summary of the content on the page No. 4
Introduction Thank you for using the “QM-Data 200” two-dimensional data processing unit. This Operation Guide presents a collection of example applications that will help you understand the basic operating procedures using the QM-Data 200. Effective use of this Operation Guide will ensure that you use the QM-Data 200 correctly, and will help you in your measurement work. Model Workpiece The model workpiece shown below is used in all the examples presented. This model workpiece is
Summary of the content on the page No. 5
Table of Contents CONVENTIONS USED IN THIS MANUAL.....................................................i Introduction............................................................................ii Model Workpiece .......................................................................ii 1 Before St
Summary of the content on the page No. 6
MEMO iv No. 99MBA038A
Summary of the content on the page No. 7
1 Before Starting Measurements 1 This chapter presents practice on the preparations which precede measurements using this data processing unit. 1.1 Outline of Data Processing Unit 1.1.1 Appearance Display portion (LCD) Power switch Key panel Fig. 1-1-1 1-1 No. 99MBA038A
Summary of the content on the page No. 8
1.1.2 Key Panel Layout Basic feature measurement AI measurement key command keys Function keys Screen switching key [LOAD] key Coordinate data [CANCEL] key input style key Coordinate [ENTER] key system alignment menu key Counter function key Measurement macro command keys Numeric keys User-defined menu keys Manual print key Cursor keys Fig. 1-1-2 Table 1-1-1 (No. 1) Key Function Basic feature measurement Used to measure and calculate basic geometric shapes. c
Summary of the content on the page No. 9
1. Before Starting Measurements Table 1-1-1 (No. 2) Key Function Automatically recognizes the type of the measured basic feature and outputs AI measurement key the results when measured points are input. Switches the screen display mode (measurement screen, counter display Screen switching key screen, etc.). Counter function key Uses the data processing unit as a simple counter. Manual print key Prints the measurement results displayed on the screen. Executes a previously registered p
Summary of the content on the page No. 10
1.1.4 Measurement Screen Measurement result window Navigation window Circle Counter Fig. 1-1-4 F1: Recalls the measured features and performs calculations, etc. F2: Recalls the measured features to adopt the representative point coordinates of those features as measured points for the current measurement. F3: Changes the measurement conditions ('Output Items', 'Auto.MeasuringCompletion'). F4: (Enables/disables input
Summary of the content on the page No. 11
1. Before Starting Measurements 1.2 Preparing for Measurement [Purpose of Practice] To learn the operating procedures from turning on the power to getting the state where measurement commands can be executed. [Operating Procedure] 1) Turn on the power for the data processing unit. 2) Set the printer output to ON. 1.2.1 Turning On the Power Table 1-2-1 No. Operation Screen display and remarks 1 Turn the power switch to ON. – 2 The Startup Screen is displayed. A little bit af
Summary of the content on the page No. 12
1.2.2 Setting Printer Output to ON (when printer is connected) NOTE Be sure to turn on the printer power before setting the printer output to ON. Table 1-2-2 No. Operation Screen display and remarks MENU 1: Output Function Menu 1 Selecting menu function 7 8 9 Press . 4 5 2 Selecting printer setting Press the numeric key corresponding to – . Selecting ON for printer 3 Use the left and right cursor keys to select “All – Results w/o Command Names” for “Co
Summary of the content on the page No. 13
2 Basic Measurements 2 This chapter presents practice for basic measurement procedures using the model workpiece. 2.1 Measuring a Circle [Purpose of Practice] To measure a circle using the model workpiece. φ4 Fig. 2-1-1 [Operating Procedure] Table 2-1-1 No. Operation Screen display and remarks 1 Preparing the workpiece Set the model workpiece on the XY table as shown below, and focus on it. – 2 Measurement function selection – Press . 2-1 No. 99MB
Summary of the content on the page No. 14
No. Operation Screen display and remarks Measuring circle (A) 3 At any three points on the circumference of circle (A), Follow the information displayed on the center the projection screen crosshairs and then press the screen to perform the measurement. [LOAD] key. 1 (A) 2 3 4 Results display The circle (A) measurement results are displayed on the N0001 screen. X = *.*** Y = *.*** D = 4.018 Diameter D NOTE • The three points that are measured sho
Summary of the content on the page No. 15
2. Basic Measurements 2.2 Measuring Angle Between Two Edges [Purpose of Practice] To measure the angle between two edges using the model workpiece. (B) (A) 150° Fig. 2-2-1 [Operating Procedure] Table 2-2-1 No. Operation Screen display and remarks Preparing the workpiece 1 Set the model workpiece on the XY table as shown below, and focus on it. – 2 Measurement function selection – Press . 3 Measuring edge (A) Measure edge (A) at two points. Follow the infor
Mitutoyo Qm-data 100 Manual
Summary of the content on the page No. 16
No. Operation Screen display and remarks Measuring edge (B) 4 Measure edge (B) at two points. Follow the information displayed on the 4 3 screen to perform the measurement. (B) 5 Results display The measurement results (A1, A2) for the angle formed by edge (A) and edge (B) are displayed on the screen. N0001 A2 X = *.*** Y = *.*** A1 A1= 150.0142 A2= 209.5818 NOTE • Note that the obtained angle (A1) varies depending on the order in which the edges
Summary of the content on the page No. 17
2. Basic Measurements 2.3 Measuring a Width [Purpose of Practice] To measure a width using the model workpiece. 2 (B) (A) Fig. 2-3-1 [Operating Procedure] Table 2-3-1 No. Operation Screen display and remarks 1 Preparing the workpiece Set the model workpiece on the XY table as shown below, and focus on it. – 2 Measurement function selection – Press . 3 Measuring side (A) Follow the information displayed on the Measure side (A) at two points. (A) screen to
Summary of the content on the page No. 18
No. Operation Screen display and remarks Measuring side (B) 4 Measure side (B) at one point. Follow the information displayed on the (B) screen to perform the measurement. 1 5 The width measurement result (LC) is displayed on the screen. LC N0001 LC= 2.001 NOTE When measuring a width, be sure to enter two points for the edge being measured first, and then enter one remaining point for the edge being measured second. TIP • If an incorrect position wa
Summary of the content on the page No. 19
2. Basic Measurements 2.4 Measuring Distance Between Two Circles [Purpose of Practice] To measure two circles to obtain the distance between them. (B) (A) 4 Fig. 2-4-1 [Operating Procedure] Table 2-4-1 No. Operation Screen display and remarks Preparing the workpiece 1 Set the model workpiece on the XY table as shown below, and focus on it. – 2 Measurement function selection – Press . 3 Measuring circle (A) Measure circle (A) at three points. Follow the info
Summary of the content on the page No. 20
No. Operation Screen display and remarks Measuring circle (B) 4 Measure circle (B) at three points. Follow the information displayed on the screen to perform the measurement. 1 (B) 2 3 Results display 5 The measurement results (LC, LS, LL) for the distance between circle (A) and circle (B) are displayed on the screen. N0001 LC= 4.006 LL= 6.011 LS= 2.001 XD= *.*** YD= *.*** (A) (B) LS LC LL TIP • The XD and YD measurement results indic
Canon software instruction manual download. Instruction Manual. OThe software screens and displays printed in this Instruction Manual may differ slightly from the actual software. OThe content of this Instruction Manual has been reviewed thoroughly. However, if you should notice any errors or omissions, please contact a Canon Service Center.